Hello,
in our network we have over 100 firewalls, divided between SSG-320M and SSG-550M, with ScreenOS and Software Version: 6.3.0r21.0.
These firewalls are clustered in pairs and having to change one of these devices, has been replaced with an SSG-550.
We have found that when we run the GET CHASSIS command on the new device, we no longer have information on the status of the fans.
On the Firewall Master (550M):
XXXXXXXXX-01 (M) -> get chassis
Chassis Environment:
Power Supply: Good
Fan1 Status: Good
Fan2 Status: Good
Fan3 Status: Good
CPU Temperature: 140'F (60'C)
System Temperature: 82'F (28'C)
Alarm Control Information:
Power failure audible alarm: enabled
Fan failure audible alarm: enabled
Temperature audible alarm: enabled
CPU alarm temperature is 158'F (70'C)
System alarm temperature is 140'F (60'C)
.....
XXXXXXXXX-01 (M) -> get system
Product Name: SSG-550M
_________________________________________-
On the Backup Firewall (550):
XXXXXXXXX-02 (B) -> get chassis
Chassis Environment:
Power Supply: Good
CPU Temperature: 122'F (50'C)
System Temperature: 77'F (25'C)
Alarm Control Information:
Power failure audible alarm: enabled
Fan failure audible alarm: enabled
Temperature audible alarm: enabled
CPU alarm temperature is 158'F (70'C)
System alarm temperature is 140'F (60'C)
Slot Information:
Name Status Slot Asm-id Serial Number Version
0 mgt Online 01bf 0158072007000055 REV 29
1 Empty
2 Empty
3 4-fe-tx-s Online 0711 PG4022 REV 15
4 Empty
5 Empty
6 Empty
XXXXXXXX-02 (B) -> get system
Product Name: SSG-550
Is this information on the SSG-550 not expected to be there?
Acalisti77